Horton Ambulance 553 (2014) – 16V625000

Defect Description For Recall

Halcore Group, Inc. (Halcore) Is Recalling Certain Model Year 2013-2016 Horton Ambulances, Models 453, 457, 503, 553, 603, And 623, Manufactured November 29, 2013, To March 1, 2016. The Affected Vehicles May Have An Improperly Sealed Cool-Tech Air-Conditioning Condenser Controller Wire Harness That Can Allow Water To Enter The Controller Housing.

Make Of Vehicle

HORTON AMBULANCE

Model Of Vehicle

553

Year

2014

Recall Campaign Number

16V625000

Component Description

Equipment:Appliance:Air Conditioner

Effect Of Defect

If Water Gets Into The Controller Housing, The Controller May Short Circuit, Increasing The Risk Of An Electrical Fire.

Fix Defect

Halcore Will Notify Owners, And Dealers Will Replace The Cool-Tech Condenser Fan Controller Assembly, Free Of Charge. Halcore Issued An Interim Notification To Owners On September 9, 2016. The Recall Began On October 26, 2016. Owners May Contact Horton Customer Service At 1-614-317-9856, Or By Email At Warranty@Hortonambulance.Com

Vehicle Manufacturer

Halcore Group, Inc.

Start Of Manufacture

20131129

End Of Manufacture

20160301

Type Of Vehicle Recall

V

Number Affected

351

Date Owners Notified

20161026

Initiated By

Mfr

Responsible Manufacturer

Halcore Group, Inc.

Date Report Received

20160826

Make Campaign Number

Part Number

Federal Motor Vehicle Safety Standard