b-51300

Mirada B-51300 – 95E025000

Vehicle recall defect – Some Temperature Sensitive Triggers Were Not X-Rayed. These Triggers Could Contain Internal VoIDS That Would Make The Triggers Susceptible To Advanced Creep Causing False Activation And Venting Of The Cng.


Mirada B-51300 – 95E014000

Vehicle recall defect – Non-Stainless Steel Balls (Chrome Plated Steel) In The Thermal Trigger Of The Pressure Relief Device Have Corroded Causing False Thermal Activation.


Mirada B-51300 – 95E005000

Vehicle recall defect – Upon Exposure To Impurities In The Natural Gas Fuel In Cold Weather, An Internal O-Ring On These Devices Can Blister During Decompression After “Fast-Fill” Refueling Resulting In Seal Leakage.