AEV Ambulance Wheelchair Van (2007) – 16V001000

Defect Description For Recall

Halcore Group, Inc. (Halcore) Is Recalling Certain Model Year 2006-2013 American Emergency Vehicles (AEV) Ambulance Wheelchair Vans Manufactured January 2, 2006 To March 15, 2013, Equipped With Certain Model S2005, S2010, S5005, S5010, S5505, And S5510 Wheelchair Lifts Manufactured By Ricon Corporation. The Affected Lifts Are Equipped With Folding Link Arms That May Have Pivot Holes That Are Too Big, Allowing The Bearings To Move Out Of Position.

Make Of Vehicle

AEV

Model Of Vehicle

AMBULANCE WHEELCHAIR VAN

Year

2007

Recall Campaign Number

16V001000

Component Description

Equipment Adaptive/Mobility

Effect Of Defect

If The Bearings Move Out Of Position, The Stowed Platform May Have Excessive Movement Resulting In Failure Of The Platform Mounting. This Failure Could Cause The Wheel Chair Lift Platform To Fall Out Of The Vehicle When The Doors Are Opened, Increasing The Risk Of Injury For The Lift Operator.

Fix Defect

Halcore Will Notify The Owners, And Ricon Dealers Will Inspect The Link Arms For Damage Or For Displaced Bearings. The Platform Will Be Inspected For Cracks. Any Damaged Parts Will Be Replaced, Free Of Charge. The Recall Began On January 13, 2016. Owners May Contact Ricon Customer Service At 1-800-322-2884 Or AEV Customer Service At 1-800-374-9749. Halcore’S Number For This Recall Is 15E-068.

Vehicle Manufacturer

Halcore Group, Inc.

Start Of Manufacture

20060102

End Of Manufacture

20130315

Type Of Vehicle Recall

V

Number Affected

9

Date Owners Notified

20160113

Initiated By

Odi

Responsible Manufacturer

Halcore Group, Inc.

Date Report Received

20160104

Make Campaign Number

1.5E-67

Part Number

Federal Motor Vehicle Safety Standard