Medtec Ambulance (2003) – 04V491000

Defect Description For Recall

On Certain Ambulances, A Diode In The Anti-Lock Braking System (Abs) Module May Experience An Electrical Short.

Make Of Vehicle

MEDTEC

Model Of Vehicle

AMBULANCE

Year

2003

Recall Campaign Number

04V491000

Component Description

Electrical System:Wiring

Effect Of Defect

The Electrical Short May Cause An Abs MalfunCTIon That Would Illuminate The Abs Warning Light, Or The Module May Overheat Resulting In A Burning Odor, Smoke, And/Or Fire. This Condition May Occur While The Vehicle Is Being Driven Or Unattended.

Fix Defect

Dealers Will Install A New Fuse In The Abs Circuit And Install A Heat Shield Over The Abs Module. The Recall Is Expected To Begin On October 8, 2004. Owners Should Contact Ford At 1-800-392-3673 Or Medtec At 1-574-534-2631. Also Ford Is Extending The Limited Warranty (For A One Time Replacement) Of The Abs Module For A Total Of 10 Years Or 150,000 Miles From The Warranty Start Date, Whichever Occurs First. If Your Vehicle Has Already Accumulated More Than 150,000 Miles, This Coverage Will Last Until September 30, 2005.

Vehicle Manufacturer

Medtec Ambulance Corporation

Start Of Manufacture

20020801

End Of Manufacture

20041130

Type Of Vehicle Recall

V

Number Affected

462

Date Owners Notified

Initiated By

Mfr

Responsible Manufacturer

Pierce Manufacturing

Date Report Received

20041015

Make Campaign Number

04S22

Part Number

Federal Motor Vehicle Safety Standard